Protection maintained for days
A VC100 connected to one MBV110 valve continues operating for up to 6 days, or up to 3 days with two valves.
12V backup battery
A compact 12V backup battery designed to keep your Assek water-damage prevention systems running, even during a power outage.
Product
The UPS012 is a compact 12V backup battery designed to keep Assek water-damage prevention systems running, including gateways, the VC100 control panel and MBV110 motorized valves, even during a power outage. Available in two capacities, 28.86 Wh and 49.95 Wh, it recharges automatically when power is restored.
When paired with the VC100 control panel, it allows equipment to keep monitoring and automatically shutting off water for several days without mains power.
Benefits
A power outage should not disable your water-damage protection.
A VC100 connected to one MBV110 valve continues operating for up to 6 days, or up to 3 days with two valves.
The 50 Wh model adds USB and 9 VDC outputs to power other Assek devices when needed.
Four-level status lights provide an immediate view of charge level, without tools or an app.
Features
The UPS012 adds rechargeable backup power to Assek equipment that must keep detecting, alerting or shutting off water during an outage.

Provides up to 6 days of backup for a VC100 connected to one MBV110 valve, or 3 days for two valves.
Available in 28.86 Wh or 49.95 Wh, with a UL Recognized internal lithium-ion battery. Four status lights show charge from 100% to below 25%.
Recharges automatically when mains power returns through a 12 VDC 3A input. Compatible with Assek gateways, VC100, MBV110 valves and the UG sensor range.
The 50 Wh model provides additional 9 VDC and USB 5V outputs. The device can be wall-mounted or placed flat without complex wiring.
Models: UPS012-29WH-O1 (28.86 Wh) and UPS012-50WH-O4 (49.95 Wh)
Battery type: Rechargeable lithium-ion, UL Recognized internal battery (UR) INR18650-2000
Voltage: 12 VDC input and output
Dimensions: 29 Wh: 111 × 60 × 26 mm; 50 Wh: 111 × 80 × 26 mm – 236 g, white enclosure
Outputs: 29 Wh: 1 × 12 VDC 2 A (5.5 × 2.1 mm DC jack); 50 Wh: 2 × 12 VDC 2 A, 1 × 9 VDC 1 A, 1 × USB 5V 3A
Backup time: VC100 + 1 MBV110 valve: about 6 days; VC100 + 2 MBV110 valves: about 3 days; UG devices: 12 to 32 hours depending on the model
Charging: 12 VDC 3A input, 5.5 × 2.1 mm DC jack
Temperature range: 0 to 45 °C
Compliance and markings: Complies with IEC 62368-1 and IEC 62133-2; CE and RoHS markings
Compatible devices: Assek gateways, VC100, MBV110 valves and UG sensor range
Installation
Connect power and the devices to protect, then place the UPS012 according to the available space.
Power supply
Always use a 12 VDC, 3 A maximum power supply for charging.
Commissioning
Turn the device on by connecting power or pressing the power button once; the status lights turn on to confirm.
Connect the devices
Connect devices to protect, such as the VC100, a gateway or a valve, to the UPS012 outputs.
Mounting
Install the device on a wall with screws or place it flat according to the available space.
Documentation
Find the model's technical and installation documents in one place.
Detailed characteristics, outputs, backup time and ordering information for the UPS012. Available in French.
Instructions for commissioning, installing and using the UPS012. Available in French.
Up to 6 days for a VC100 connected to one MBV110 valve, and about 3 days with two valves.
The 29 Wh model offers one 12 VDC 2 A output, while the 50 Wh model adds a second 12 VDC output, a 9 VDC output and a USB output to power additional devices.
Yes. When mains power is restored, the UPS012 automatically recharges its battery through the 12 VDC 3A input.